Přehled
THJ-2201 je syntetický výzkumný kanabinoid používaný jako referenční standard pro výzkum kanabinoidních receptorů a forenzní analýzu.
The history of THJ-2201 is part of synthetic cannabinoid research that accelerated following the identification of the endocannabinoid system in the 1990s. Scientists investigating CB1 and CB2 receptor pharmacology synthesized numerous compounds to understand structure-activity relationships. THJ-2201 emerged as researchers explored novel cannabinoid receptor agonists. Research into synthetic cannabinoids has focused on understanding how different structural scaffolds and substituents affect cannabinoid receptor binding affinity, selectivity, and functional activity. THJ-2201 became a subject of analytical and pharmacological research as scientists sought to characterize its properties and develop detection methods. The compound has been studied using chromatographic and spectroscopic techniques. Contemporary research utilizing THJ-2201 focuses on cannabinoid receptor pharmacology, endocannabinoid system function, and forensic analytical method development. The compound serves as an important reference standard in toxicology laboratories and contributes to research on cannabinoid mechanisms and receptor function in controlled laboratory settings.
THJ-2201 acts as an agonist at CB1 and/or CB2 cannabinoid receptors, mimicking endocannabinoid function. This mechanism makes it valuable for research on cannabinoid receptor pharmacology and detection method development.
THJ-2201 holds significant value in scientific research due to its well-characterized properties and legal accessibility in several jurisdictions. This enables comprehensive pharmacological studies and analytical method development.
High-purity THJ-2201 (≥98% by HPLC) serves as a crucial reference standard in research laboratories, quality control testing, and academic research settings. Its consistent quality makes it ideal for method development and validation.
Technické Specifikace
Proč Výzkumníci Volí THJ-2201
🔬Cannabinoid Receptor Research
THJ-2201 is used as a reference standard for studying CB1 and CB2 cannabinoid receptor pharmacology. Its consistent purity enables analytical method validation for synthetic cannabinoids.
🧬Forensic Toxicology
Research teams utilize THJ-2201 to develop detection methods for novel synthetic cannabinoids in biological samples, supporting public health and forensic laboratories.
📊Receptor Binding Studies
High-purity THJ-2201 enables research on cannabinoid receptor binding affinity, selectivity, and functional activity, advancing understanding of endocannabinoid system pharmacology.
Výzkumné aplikace
Důležité Upozornění: Tato sloučenina je určena pouze pro výzkumné a analytické účely. Není určena pro lidskou spotřebu.
Chemické Vlastnosti
Údaje o Rozpustnosti
Analytické metody
Externí Databáze
Bezpečnost a Informace o Nebezpečí
Hazard Statements (H):
- •H302: Harmful if swallowed
- •H315: Causes skin irritation
- •H319: Causes serious eye irritation
- •H335: May cause respiratory irritation
Precautionary Statements (P):
- •P261: Avoid breathing dust/fume/gas/mist/vapors/spray
- •P264: Wash hands thoroughly after handling
- •P280: Wear protective gloves/protective clothing/eye protection/face protection
- •P301+P312: IF SWALLOWED: Call a POISON CENTER or doctor if you feel unwell
Běžné Účinky
Právní status podle země
Klikněte na zemi pro zobrazení podrobných právních informací a údajů o přepravě.
Často kladené otázky
Q:What is THJ-2201 used for in research?
THJ-2201 is primarily used as an analytical reference standard in forensic toxicology, pharmacological research, quality control testing, and method development. It is NOT intended for human or veterinary use.
Q:How should THJ-2201 be stored?
Store THJ-2201 at -20°C in a dark, dry environment. Protect from light and moisture to maintain stability. When stored properly, research chemicals have a shelf life of approximately 2 years. Always use amber glass vials with proper sealing.
Q:What analytical methods are used to test THJ-2201 purity?
High-Performance Liquid Chromatography with UV detection (HPLC-UV) is the primary method for purity analysis. Additional confirmation methods include Gas Chromatography-Mass Spectrometry (GC-MS), Liquid Chromatography-Mass Spectrometry (LC-MS/MS), and Nuclear Magnetic Resonance (NMR) spectroscopy.
Q:What is the minimum purity guaranteed for EuroChems THJ-2201?
All EuroChems THJ-2201 products are guaranteed to be ≥98% pure as verified by HPLC analysis. Each batch includes a Certificate of Analysis (COA) confirming purity specifications.
Související Výzkum
Zdroje
Podobné Sloučeniny
Bezpečnostní Upozornění
Pouze pro výzkumné účely. NENÍ URČENO K LIDSKÉ SPOTŘEBĚ. Vyžaduje správnou laboratorní manipulaci.